Skip to content

CVE-2026-114625: Arista VeloCloud Orchestrator (VCO) On-Prem SQL Injection & Superuser Privilege Escalation (CISA KEV) & Companion Okta Access Gateway / Snap7 Flaws (CVE-2026-115547, CVE-2026-115546, CVE-2026-115723)

Density:
C-Level Executive Briefing CVE-2026-114625 CRITICAL SCORE 97/100

Critical perimeter SD-WAN orchestration, enterprise identity gateway, and industrial control vulnerability cluster disclosed between October 23 and October 24, 2026. Under CISA KEV CVE-2026-114625 (CVSS 9.9), on-premises deployments of Arista VeloCloud Orchestrator (VCO) prior to 5.2.3.18, 6.1.3.10, and 6.4.2.12 suffer from a low-complexity SQL injection vulnerability actively exploited in the wild as a zero-day (with hostile telemetry observed from 74.82.197.86 and 38.54.50.151). Any authenticated userโ€”including low-privilege Enterprise Read-Only accountsโ€”can inject SQL payloads to escalate privileges to a local 'superuser operator', unlocking restricted internal administrative APIs across the entire SD-WAN fabric. Analyzed alongside Okta Access Gateway (OAG) < 2026.10.2 sign-on authentication source spoofing (CVE-2026-115546, CVSS 8.1) chained with Admin Console configuration input validation OS command execution (CVE-2026-115547, CVSS 9.1), and VulnCheck weaponized Snap7 <= 1.4.3 BRecv / CheckAsBRecvCompletion out-of-bounds write (CVE-2026-115723) in Siemens S7 industrial gateways.

HYBRID

HERMES THREAT SCORE & SD-WAN ORCHESTRATOR / ACCESS GATEWAY EVALUATION

Target: Arista VeloCloud Orchestrator (VCO) On-Prem SQL Layer, Okta Access Gateway (OAG) Sign-On / Admin Console & Snap7 BRecv()
Confidence: 99%
97 / 100
CRITICAL

Measures real-world operational relevance, exploit weaponization, and active threat posture.

Dimension Breakdown
Exploitability 19 / 20
Threat Activity 20 / 20
Weaponization 20 / 20
Exposure 19 / 20
Prevalence 18 / 20
Impact 20 / 20
Exploit Maturity 20 / 20
Attack Chain Potential 20 / 20
โš–๏ธ Divergence & Operational Rationale

CVSS v3.1 scores CVE-2026-114625 at 9.9 (Critical) with Scope Changed (S:C) because any authenticated tenant user (PR:L)โ€”even a strictly read-only monitoring accountโ€”can break out of tenant isolation via SQL injection to become a global 'superuser operator' and compromise the VCO host and all downstream SD-WAN edges. The Hermes Threat Score elevates this cluster to 97 (CRITICAL) with a Hermes Agentic Security Score (HASS) of 90 (CRITICAL). Added to the CISA Known Exploited Vulnerabilities (KEV) catalog on October 23, 2026 following confirmed zero-day exploitation in the wild from 74.82.197.86 and 38.54.50.151, CVE-2026-114625 represents the second consecutive month of active zero-day weaponization against Arista VeloCloud Orchestrator (following CVE-2026-93952). Combined with the two-stage Okta Access Gateway SAML authentication source bypass and Admin Console OS command injection chain (CVE-2026-115546 + CVE-2026-115547), adversaries can pivot seamlessly across identity perimeters and WAN control planes.

๐Ÿ•ธ๏ธ Connected Knowledge Graph & Provenance

CVE-2026-114625: Arista VeloCloud Orchestrator (VCO) On-Prem SQL Injection & Superuser Privilege Escalation (CISA KEV) & Companion Okta Access Gateway / Snap7 Flaws (CVE-2026-115547, CVE-2026-115546, CVE-2026-115723)VULNERABILITY

Connected Nodes: 1
Active Relationships (Outgoing)
→ affectsPRODUCTArista VeloCloud Orchestrator
98% VERY_HIGH

Software platform affected by security vulnerabilities and agentic attack patterns.

๐Ÿ” Why is this related? (Evidence & Provenance)

“Confirmed security vulnerability in Arista VeloCloud Orchestrator documented in Hermes dossier.”

Supporting Verified Evidence:

Between October 23 and October 24, 2026, the Cybersecurity and Infrastructure Security Agency (CISA KEV), Arista Networks, Okta, and VulnCheck Initial Access Intelligence disclosed three critical vulnerability clusters targeting enterprise SD-WAN orchestration planes (Arista VeloCloud Orchestrator), identity and reverse-proxy access gateways (Okta Access Gateway), and industrial Ethernet S7 communication stacks (Snap7):

  1. CVE-2026-114625 (CWE-89, CVSS 9.9 Critical / CISA KEV โ€” Arista VeloCloud Orchestrator On-Prem < 5.2.3.18 / < 6.1.3.10 / < 6.4.2.12 SQL Injection & Superuser Operator Privilege Escalation): Actively exploited in the wild as a zero-day and added to the CISA KEV catalog on October 23, 2026 (federal remediation due date: November 13, 2026). While requiring an authenticated session (PR:L), the flaw allows any authenticated roleโ€”including the lowest-privileged Enterprise Read-Only user or a compromised monitoring API tokenโ€”to execute a low-complexity SQL injection query. The attacker elevates their session to a local superuser operator, gaining unrestricted access to internal-only VCO administrative endpoints, tenant routing tables, IPSec/VCRP tunnel keys, and orchestrator host functions. Arista threat telemetry identified active exploitation originating from 74.82.197.86 and 38.54.50.151.
  2. CVE-2026-115547 (CWE-78 / CWE-20, CVSS 9.1 Critical) & CVE-2026-115546 (CWE-287, CVSS 8.1 High) โ€” Okta Access Gateway (< 2026.10.2) Sign-On Authentication Source Spoofing to Admin Console OS Command Execution Chain: Affects Okta Access Gateway (OAG) on-premises appliances prior to version 2026.10.2. Under CVE-2026-115546, OAG fails to validate the selected authentication source parameter during sign-on; an authenticated regular user with an active session can tamper with the authentication source parameter to generate a SAML assertion that grants administrative access to the OAG Admin Console. Once inside the Admin Console, CVE-2026-115547 allows the attacker to supply specially formatted configuration values that bypass input validation and execute arbitrary operating system commands on the underlying appliance under the OAG service account.
  3. CVE-2026-115723 (CWE-787, CVSS 9.5 Weaponized โ€” Snap7 <= 1.4.3 Out-of-Bounds Write via BRecv and CheckAsBRecvCompletion): Flagged by VulnCheck on October 24, 2026. In the passive partner implementation of Snap7 (widely embedded in Siemens S7 SCADA, HMI, and OT telemetry gateways), a peer connecting from a configured partner address can send a BSend PDU declaring an unvalidated total payload size up to 65,535 bytes while transmitting a short initial fragment, causing BRecv and CheckAsBRecvCompletion to execute an out-of-bounds memcpy past the allocated application buffer.

1. CVE-2026-114625: Authenticated Read-Only SQL Injection to superuser operator Takeover in Arista VCO

Section titled โ€œ1. CVE-2026-114625: Authenticated Read-Only SQL Injection to superuser operator Takeover in Arista VCOโ€

Arista VeloCloud Orchestrator (VCO) manages multi-tenant SD-WAN fabrics across three privilege tiers: Operator (global system administration), Partner (MSP management), and Enterprise (tenant administration, down to Enterprise Read-Only). In addition, VCO contains internal diagnostic and system orchestration endpoints restricted to a local superuser operator role intended exclusively for internal platform operations.

In VCO release trains 5.2.x prior to 5.2.3.18, 6.1.x prior to 6.1.3.10, and 6.4.x prior to 6.4.2.12, an authenticated portal/API handler constructs a backend relational database query using unsanitized user-controlled parameters without binding them via parameterized prepared statements:

// CONCEPTUAL RECONSTRUCTION: Arista VeloCloud Orchestrator (VCO) On-Prem
// Vulnerable Release Trains: < 5.2.3.18, < 6.1.3.10, < 6.4.2.12 (CVE-2026-114625)
async function handleEnterprisePortalQuery(req, res) {
const session = req.vcoSession; // Validated for ANY authenticated user (e.g., Enterprise Read-Only)
if (!session || !session.isAuthenticated) {
return res.status(401).json({ error: "Authentication required" });
}
const { filterField, filterExpr } = req.body;
// FLAW (CWE-89): Unsanitized string interpolation in SQL query accessible to Read-Only users.
// Attackers inject SQL clauses or stacked/UNION expressions to read/modify session and operator
// role bindings, elevating the session's effective privilege to 'superuser operator' (isSuperuser = 1).
const rawSql = `SELECT id, name, logicalId, status FROM vco_enterprise_objects ` +
`WHERE enterpriseId = ${Number(session.enterpriseId)} AND ${filterField} = '${filterExpr}'`;
const rows = await dbPool.query(rawSql);
return res.json({ data: rows });
}

By exploiting this SQL injection primitive from a low-privilege account:

  1. Role & Session Escalation to superuser operator: The attacker reads or manipulates internal operator session/token tables in the VCO database, binding their active session or forging a token associated with the internal superuser operator profile.
  2. Invocation of Restricted Internal VCO Functionalities: Armed with superuser operator privileges, the attacker accesses hidden internal management routes (such as system-level configuration overrides, diagnostic command hooks, and cross-tenant edge provisioning) that are blocked even to normal admins.

2. CVE-2026-115546 & CVE-2026-115547: Two-Stage Okta Access Gateway (OAG) SAML Auth-Source Spoofing to OS Command Injection

Section titled โ€œ2. CVE-2026-115546 & CVE-2026-115547: Two-Stage Okta Access Gateway (OAG) SAML Auth-Source Spoofing to OS Command Injectionโ€

In Okta Access Gateway (OAG) < 2026.10.2, two vulnerabilities combine into a devastating privilege-escalation-to-root-shell chain:

  1. Stage 1 โ€” Authentication Source Parameter Tampering (CVE-2026-115546, CVSS 8.1): When a user with an active authenticated session initiates a sign-on flow, OAG accepts a request parameter selecting the authentication source (auth_source / IDP binding) without verifying that the selected source is authorized for the target administrative realm. By modifying the authentication source parameter during sign-on, a standard user causes OAG to mint a valid SAML assertion mapped to the OAG Admin Console.
  2. Stage 2 โ€” Admin Console Configuration Value Command Injection (CVE-2026-115547, CVSS 9.1): Inside the OAG Admin Console, configuration handlers accept specially formatted setting values (such as custom proxy directives, Kerberos/LDAP settings, or network parameters) and pass them to underlying appliance configuration scripts without strict shell/directive sanitization, executing arbitrary OS commands under the oag service account.
# CONCEPTUAL RECONSTRUCTION: Okta Access Gateway (OAG < 2026.10.2)
# Stage 1 (CVE-2026-115546): Unvalidated Authentication Source Selection During Sign-On
def process_oag_sso_signon(request, active_user_session):
# FLAW 1 (CVE-2026-115546): Trusts user-supplied `selected_auth_source` parameter
# when an active user session exists, minting a SAML assertion valid for the Admin Console!
auth_source = request.POST.get("selected_auth_source")
saml_assertion = generate_saml_assertion(
subject=active_user_session.username,
source=auth_source,
target_app="OAG_ADMIN_CONSOLE"
)
return redirect_with_saml(saml_assertion)
# Stage 2 (CVE-2026-115547): Specially Formatted Config Value -> OS Command Execution
def apply_admin_console_config(admin_session, config_payload):
# FLAW 2 (CVE-2026-115547): Specially formatted configuration value bypasses input validation
# and injects shell commands into the underlying OAG appliance helper script.
worker_param = config_payload.get("gateway_directive")
os.system(f"/opt/oag/bin/configure_gateway_service --directive \"{worker_param}\"")

3. CVE-2026-115723: Snap7 (<= 1.4.3) BRecv & CheckAsBRecvCompletion Out-of-Bounds Write

Section titled โ€œ3. CVE-2026-115723: Snap7 (<= 1.4.3) BRecv & CheckAsBRecvCompletion Out-of-Bounds Writeโ€

In Snap7 <= 1.4.3 (src/core/s7_partner.cpp), the Block Oriented Data Transfer (BSend / BRecv) state machine allows a passive partner to receive multi-fragment S7 blocks from an active partner. When the first BSend PDU arrives, the header declares the total transfer size (TotalLength, up to 65,535 bytes). If the receiving application registered a smaller receive buffer via BRecv(R_ID, pUsrData, Size), CheckAsBRecvCompletion failed to validate that TotalLength and subsequent fragment offsets did not exceed the callerโ€™s allocated pUsrData capacity, triggering an out-of-bounds memcpy (CWE-787).

flowchart TD
subgraph AristaVCO["CVE-2026-114625 (CISA KEV): Arista VeloCloud Orchestrator (< 5.2.3.18 / 6.1.3.10 / 6.4.2.12)"]
V1["Attacker with Low-Privilege Session (e.g., Enterprise Read-Only)<br/>Observed Zero-Day Threat IPs: 74.82.197.86 & 38.54.50.151"]
V2["CWE-89: Low-Complexity SQL Injection in VCO Database Layer"]
V3["Privilege Escalation to Local 'superuser operator'<br/>Unrestricted Access to Internal VCO Functions & SD-WAN Fabric"]
V1 --> V2 --> V3
end
subgraph OktaOAG["CVE-2026-115546 + CVE-2026-115547: Okta Access Gateway (< 2026.10.2)"]
O1["CVE-2026-115546: Active User Modifies Auth Source Parameter<br/>Forges SAML Assertion for OAG Admin Console"]
O2["CVE-2026-115547: Specially Formatted Admin Console Config Value<br/>Arbitrary OS Command Execution Under OAG Service Account"]
O1 --> O2
end
subgraph Snap7ICS["CVE-2026-115723: Snap7 (<= 1.4.3) Industrial S7 Partner"]
S1["Peer Sends BSend PDU Declaring TotalLength up to 65,535 Bytes<br/>Out-of-Bounds memcpy in BRecv / CheckAsBRecvCompletion"]
end
style V2 fill:#ff1a1a,stroke:#800000,color:#ffffff
style V3 fill:#ff4d4d,stroke:#990000,color:#ffffff
style O1 fill:#ff6600,stroke:#993300,color:#ffffff
style O2 fill:#ff1a1a,stroke:#800000,color:#ffffff
style S1 fill:#ff6600,stroke:#993300,color:#ffffff

To detect active zero-day exploitation of Arista VeloCloud Orchestrator (CVE-2026-114625), SAML auth-source tampering and Admin Console command injection on Okta Access Gateway (CVE-2026-115546 / CVE-2026-115547), and Snap7 BSend/BRecv buffer overflows (CVE-2026-115723), deploy the following multi-platform detection suite:

title: Arista VeloCloud Orchestrator Zero-Day SQLi & Okta Access Gateway SAML/Admin RCE (CVE-2026-114625 / CVE-2026-115547 / CVE-2026-115546)
id: 114625a1-2026-4b88-9c12-velocloudkev24
status: experimental
description: Detects active exploitation indicators for Arista VeloCloud Orchestrator CVE-2026-114625 (known attacker IPs 74.82.197.86 and 38.54.50.151, SQL injection payloads in portal/rest API calls, or unexpected superuser operator role invocation) and Okta Access Gateway CVE-2026-115546 / CVE-2026-115547 exploitation.
references:
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?search_api_fulltext=CVE-2026-114625
- https://nvd.nist.gov/vuln/detail/CVE-2026-114625
- https://nvd.nist.gov/vuln/detail/CVE-2026-115547
- https://nvd.nist.gov/vuln/detail/CVE-2026-115546
author: Hermes Threat Intelligence
date: 2026/10/24
logsource:
category: webserver
detection:
selection_vco_known_threat_ips:
c-ip:
- '74.82.197.86'
- '38.54.50.151'
selection_vco_sqli_api:
cs-uri-stem|contains:
- '/portal/rest/'
- '/api/sdwan/'
request_body|contains:
- 'UNION SELECT'
- 'SELECT '
- 'isSuperuser'
- 'operator'
- 'SLEEP('
- 'WAITFOR '
selection_oag_admin_config_injection:
cs-uri-stem|contains:
- '/admin/config'
- '/oag/admin/'
request_body|contains:
- '$('
- '`'
- ';sh '
- ';bash '
- '|nc '
condition: selection_vco_known_threat_ips or selection_vco_sqli_api or selection_oag_admin_config_injection
falsepositives:
- Rare legitimate administrative custom config strings (validate against change management tickets)
level: critical
tags:
- attack.initial_access
- attack.privilege_escalation
- attack.execution
- attack.t1190
- attack.t1078
- cve.2026-114625
- cve.2026-115547
- cve.2026-115546

  1. Upgrade Arista VeloCloud Orchestrator On-Prem to >= 5.2.3.18 / 6.1.3.10 / 6.4.2.12 (CVE-2026-114625, CISA KEV Due Date: 2026-11-13):
    • Immediately upgrade on-premises VeloCloud Orchestrator deployments to the fixed maintenance release for your active train:
      • 5.2.x Train: Upgrade to 5.2.3.18 or later.
      • 6.1.x Train: Upgrade to 6.1.3.10 or later.
      • 6.4.x Train: Upgrade to 6.4.2.12 or later.
    • (Note: Arista-hosted cloud VCO instances were patched automatically by Arista; VeloCloud Edges and VeloCloud Gateways are not affected).
    • Network Isolation & Credential Hygiene: Remove public Internet exposure of the VCO web management UI and REST API, restricting access strictly to out-of-band administrative jump hosts or zero-trust VPNs. Block 74.82.197.86 and 38.54.50.151 at perimeter firewalls, audit all superuser operator sessions, and rotate all VCO database and user credentials.
  2. Upgrade Okta Access Gateway (OAG) to >= 2026.10.2 (CVE-2026-115547 & CVE-2026-115546):
    • Upgrade all Okta Access Gateway appliances to version 2026.10.2 or later, which enforces strict authentication source validation during sign-on (CVE-2026-115546) and sanitizes configuration inputs in the Admin Console (CVE-2026-115547). Audit OAG SAML assertion logs for Admin Console logins originating from non-administrative identity sources.
  3. Harden & Patch Snap7 Industrial Gateways (CVE-2026-115723):
    • Apply upstream bounds-checking fixes in Snap7 (s7_partner.cpp) to verify TotalLength <= UsrDataSize in BRecv and CheckAsBRecvCompletion, and enforce strict industrial firewall ACLs on TCP port 102 (ISO-on-TSAP).